@@ -457,6 +457,7 @@ static void knc_titan_poll(struct thr_info * const thr)
|
|
|
}
|
|
|
if ((!work_accepted) || (NULL == knccore))
|
|
|
break;
|
|
|
+ bool was_flushed = false;
|
|
|
if (knc->need_flush[asic] || need_replace) {
|
|
|
struct work *work1, *tmp1;
|
|
|
applog(LOG_NOTICE, "%s: Flushing stale works (%s)", knccore->proc->dev_repr,
|
|
|
@@ -470,6 +471,7 @@ static void knc_titan_poll(struct thr_info * const thr)
|
|
|
}
|
|
|
}
|
|
|
delay_usecs = 0;
|
|
|
+ was_flushed = true;
|
|
|
}
|
|
|
--knc->workqueue_size;
|
|
|
DL_DELETE(knc->workqueue, work);
|
|
|
@@ -478,6 +480,11 @@ static void knc_titan_poll(struct thr_info * const thr)
|
|
|
if (++(knc->next_slot[asic]) > KNC_TITAN_MAX_WORK_SLOT_NUM)
|
|
|
knc->next_slot[asic] = KNC_TITAN_MIN_WORK_SLOT_NUM;
|
|
|
++workaccept;
|
|
|
+ /* If we know for sure that this work was urgent, then we don't need to hurry up
|
|
|
+ * with filling next slot, we have plenty of time until current work completes.
|
|
|
+ * So, better to proceed with other ASICs. */
|
|
|
+ if (was_flushed)
|
|
|
+ break;
|
|
|
}
|
|
|
}
|
|
|
|