Luke Dashjr
|
c9e4f1d725
Tree-Merge commit '03309a1' into bfgminer
|
13 years ago |
Con Kolivas
|
1935865537
Receive failures in recv_line should unconditionally fail.
|
13 years ago |
Con Kolivas
|
fd3adbc734
Use sock_blocks function for stratum send and receive.
|
13 years ago |
Con Kolivas
|
18a62213e5
Avoid applog under stratum_lock in __stratum_send.
|
13 years ago |
Con Kolivas
|
60560cb0a0
Create an OS specific sock_blocks function.
|
13 years ago |
Con Kolivas
|
6b0dac2dac
There should be no error response code with return value 0 in recv_line.
|
13 years ago |
Con Kolivas
|
1fe0575b93
Check for errors on stratum recv for any recv return value less than 1 and only parse the response if it's positive.
|
13 years ago |
Con Kolivas
|
69aa7ed368
Avoid applog under stratum_lock in recv_line.
|
13 years ago |
Con Kolivas
|
03309a1dab
Differentiate socket closed from socket error in recv_line.
|
13 years ago |
Luke Dashjr
|
260c64b6ce
Stratum: Include pool number in send/recv protocol logging
|
13 years ago |
Kano
|
b30f9bb72a
bflsc unres the res
|
13 years ago |
Kano
|
dd8fe19bab
bflsc tidy up getinfo() and add to api
|
13 years ago |
Kano
|
55b3d407c5
bflsc guess device ~based on current V1 Jalapeno engine count
|
13 years ago |
Kano
|
de009dab01
bflsc only need one xlinkstr
|
13 years ago |
Kano
|
66154e9f2b
bflsc flush/clear output que when we initialise
|
13 years ago |
Kano
|
ea8aa1aa41
bflsc seperate BFLSC_QRES
|
13 years ago |
Kano
|
4bfa4c3091
bflsc queue_full shouldn't ask for more work if device is zombie
|
13 years ago |
Con Kolivas
|
4f0f5fb791
Make the scan sleep time after scanwork in bflsc dynamic to keep queues between watermark levels.
|
13 years ago |
Con Kolivas
|
b0e6f68b65
Remove unused temp counts in bflsc.
|
13 years ago |
Con Kolivas
|
e70e7b5b7e
Calculate a rolling 5 min average set of temperatures for bflsc.
|
13 years ago |
Con Kolivas
|
31fc0bc766
Damp the display of voltage for BFLSC devices.
|
13 years ago |
Con Kolivas
|
d6720ee0aa
Damp the temperature display measurement for bflsc since it fluctuates so wildly.
|
13 years ago |
Kano
|
bd4d04b260
bflsc add volt stats
|
13 years ago |
Con Kolivas
|
21fd80dfa4
Handle failed tolines command in bflsc driver.
|
13 years ago |
Con Kolivas
|
6db9745287
Can use a read lock instead of a write lock in bflsc scanwork.
|
13 years ago |
Con Kolivas
|
045d0362e7
Since we are filling a queue on the bflsc devices, there is no need to run through scanwork frequently provided we use the restart_wait function to abort early during a block change.
|
13 years ago |
Con Kolivas
|
f1624e13a9
Remove flushed work in bfl scanwork from the hash table.
|
13 years ago |
Con Kolivas
|
11baa32792
Set correct device in process_nonces in bflsc driver.
|
13 years ago |
Kano
|
93e3e8c90e
bflsc add work reply INPROCESS: missing from the spec
|
13 years ago |
Kano
|
5121163ef2
bflsc put in some error messages not yet written
|
13 years ago |